Fire Protection
Deluge Valves
77DE-EL-PR Deluge Valve, Electrically Controlled Pressure Reducing Remote Reset
Product Description
Armaş “77DE-EL-PR” is an electrically controlled, pressure reducing remote reset deluge valve that works with electrically controlled line pressure. As long as there is no electricity to the solenoid valve, the valve is closed. When electricity is supplied to the solenoid valve, the valve opens itself. According to the setting pressure of the pilot valve, the valve regulates itself and gives the desired output pressure. When the power is cut off, the valve closes itself tight. Emergency release valve is available as standard.
Fire Protection
Deluge Valves
- 77DE-EL-MR-Deluge Valve, Electrically Activated, Manual (Local) Reset
- 77DE-EL-RR-Deluge Valve, Electrically Activated, Remote Reset
- 77DE-PN-MR-Deluge Valve, Pneumatically Activated, Manual (Local) Reset
- 77DE-PN-RR-Deluge Valve, Pneumatically Activated, Remote Reset
- 77DE-EL-HRV Deluge Valve, Electrically or Hydraulically Controlled Anti-Columning
- 77DE-EL-HRV-MR Deluge Electrically or Hydraulically Controlled Anti-Columning Manual Reset
- 77DE-EL-HRV-PR Deluge Valve, Electrically or Hydraulically Controlled Anti-Columning Pressure Reducing
- 77DE-EL-HRV-PR-MR Deluge Valve, Electrically or Hydraulically Controlled Anti-Columning Pressure Reducing Manual Reset
- 77DE-EL-PORV Deluge Valve, Electrically or Pneumatically Controlled
- 77DE-EL-PORV-MR Deluge Valve, Electrically or Pneumatically Controlled Manual Reset
- 77DE-EL-PORV-PR Deluge Valve, Electrically or Pneumatically Controlled Pressure Reducing
- 77DE-EL-PORV-PR-MR Deluge Valve, Electrically or Pneumatically Controlled Pressure Reducing Manual Reset
- 77DE-HM Deluge Valve, Hydraulically Controlled
- 77DE-HM-MR Deluge Valve, Hydraulically Controlled Manual Reset
- 77DE-HRV Deluge Valve, Hydraulically Controlled Anti-Columning
- 77DE-HRV-MR Deluge Valve, Hydraulically Controlled Anti-Columning Manual Reset
- 77DE-HRV-PR Deluge Valve, Hydraulically Controlled Anti-Columning Pressure Reducing
- 77DE-HRV-PR-MR Deluge Valve, Hydraulically Controlled Anti-Columning Pressure Reducing Manual Reset
- 77DE-PORV-PR Deluge Valve, Pneumatically Controlled Pressure Reducing
- 77DE-PORV-PR-MR Deluge Valve, Pneumatically Controlled Pressure Reducing Manual Reset
- 77DE-EL-PR Deluge Valve, Electrically Controlled Pressure Reducing Remote Reset
- 67DE-EL-AL Electric Activated Deluge Valve
- 67DE-EL Electric Activated Deluge Valve
- Technicial Specifications
Valve Type: Globe Type, Diaphragm Actuated, Disc Closed
Diameters: 2” (Ø50) - 8” (Ø200)
Rated Pressure: 300 psi, 21 bar
Connection Type: Flanged
Solenoid: 2/2 Way N.C. Solenoid 24V DC