67DE-EL Electric Activated Deluge Valve
Product Description
Armaş “67DE-EL” series electrically activated deluge valves which are used for fire protection lines, open with an electric signal from a controller or a control board. Electrically activated deluge valves are used in fire protection lines with gas / smoke detectors and open nozzles / sprinklers. A 3 way solenoid valve on the deluge valve activates a relay pilot valve on the deluge valve. The relay pilot valve opens the deluge valve quickly and then the deluge valve lets water or foam concentration which is ready, flow to open nozzles / sprinklers. When the electric signal end, the deluge valve close tightly.
- 77DE-EL-MR-Deluge Valve, Electrically Activated, Manual (Local) Reset
- 77DE-EL-RR-Deluge Valve, Electrically Activated, Remote Reset
- 77DE-PN-MR-Deluge Valve, Pneumatically Activated, Manual (Local) Reset
- 77DE-PN-RR-Deluge Valve, Pneumatically Activated, Remote Reset
- 77DE-EL-HRV Deluge Valve, Electrically or Hydraulically Controlled Anti-Columning
- 77DE-EL-HRV-MR Deluge Electrically or Hydraulically Controlled Anti-Columning Manual Reset
- 77DE-EL-HRV-PR Deluge Valve, Electrically or Hydraulically Controlled Anti-Columning Pressure Reducing
- 77DE-EL-HRV-PR-MR Deluge Valve, Electrically or Hydraulically Controlled Anti-Columning Pressure Reducing Manual Reset
- 77DE-EL-PORV Deluge Valve, Electrically or Pneumatically Controlled
- 77DE-EL-PORV-MR Deluge Valve, Electrically or Pneumatically Controlled Manual Reset
- 77DE-EL-PORV-PR Deluge Valve, Electrically or Pneumatically Controlled Pressure Reducing
- 77DE-EL-PORV-PR-MR Deluge Valve, Electrically or Pneumatically Controlled Pressure Reducing Manual Reset
- 77DE-HM Deluge Valve, Hydraulically Controlled
- 77DE-HM-MR Deluge Valve, Hydraulically Controlled Manual Reset
- 77DE-HRV Deluge Valve, Hydraulically Controlled Anti-Columning
- 77DE-HRV-MR Deluge Valve, Hydraulically Controlled Anti-Columning Manual Reset
- 77DE-HRV-PR Deluge Valve, Hydraulically Controlled Anti-Columning Pressure Reducing
- 77DE-HRV-PR-MR Deluge Valve, Hydraulically Controlled Anti-Columning Pressure Reducing Manual Reset
- 77DE-PORV-PR Deluge Valve, Pneumatically Controlled Pressure Reducing
- 77DE-PORV-PR-MR Deluge Valve, Pneumatically Controlled Pressure Reducing Manual Reset
- 77DE-EL-PR Deluge Valve, Electrically Controlled Pressure Reducing Remote Reset
- 67DE-EL-AL Electric Activated Deluge Valve
- 67DE-EL Electric Activated Deluge Valve
- Available Models
- Typical Applications
Valve Type: Straight Type, Diaphragm Actuated, Diaphragm Closed
Nominal Diameter: Ø50-Ø200 (2”-8”)
Maximum Working Temperature: 80℃ (176℉)
Maximum Working Pressure: 16 bar (230 psi)
Body: Ductile Iron (GGG40)
Coating: Epoxy Powder
Flange Dimensions: ISO, EN, ANSI
Water / Foam Concentration Fire Protection Systems
Open Nozzle / Sprinklers Applications
Chemical Facilities
Flamble Materials Storages
Petroleum / Gas Facilities